Model |
|
|
WS24SL |
Indoor Unit |
|
|
WS24SLN |
Outdoor Unit |
|
|
WS24SLU |
Rated Capacity
|
Cooling kw |
|
7.1 |
Heating kw |
|
7.7 |
Capacity Range
|
Cooling kw min – max |
|
1 – 8 |
Heating kw min – max |
|
1 – 8.5 |
Power Input
|
Cooling Rated |
|
0.17 – 2.75 |
Heating Rated |
|
0.2 – 3.05 |
Running
Current
|
Cooling Rated |
|
1.20 – 11.60 |
Heating Rated |
|
1.40 – 12.70 |
EER |
W/W |
|
3.3 |
AEER |
– |
|
3.3 |
COP |
W/W |
|
3.67 |
ACOP |
– |
|
3.66 |
Energy Label / Star Ratings
|
Cooling |
|
4.0,4.0,4.0 |
Heating |
|
3.0,2.5,1.5 |
Power Supply |
|
|
1Ph, 220-240V, 50Hz |
Indoor
|
Air Flow Rate
|
Cooling, Max / H / M / L |
383/283/233/183 |
Heating, Max / H / M / L |
433/333/283/233 |
Sound Pressure Level |
Cooling, Max / H / M / L / SL |
– / 46 / 41 / 36 / 27 |
Dimensions (W × H × D) |
Net |
1060 x 360 x 265 |
Weight |
Net |
16.6 |
Outdoor
|
Compressor |
|
Twin Rotary |
Condenser |
Corrosion Protection |
Gold |
Sound Pressure Level
|
Cooling, Rated |
49 |
Heating, Rated |
52 |
Sound Power Level |
|
63 |
Dimensions* (W × H × D) Net |
|
870 x 650 x 330 |
Weight – Net |
|
45.7 |
Operation
Range
|
Cooling |
-10 ~ 48 |
|
Heating |
-10 ~ 24 |
Circuit Breaker A |
|
|
20 |
Power Supply Guide No |
|
|
3 Core + Earth |
Power Supply to Unit – |
|
|
Outdoor |
Power and Communication Cable – No. x mm2 |
|
|
4 x 1 (including Earth) |
|
|
|
|
Piping
|
Size
|
Liquid |
ø 6.35 (1/4) |
Gas |
ø 12.7 (1/2) |
Connections Method |
Indoor / Outdoor |
Flared / Flared |
Drain Hose Size |
O.D, I.D |
mm |
20/15 |
Between Indoor & Outdoor
|
Piping Length
|
Min ~ Max m |
`3-30 |
Pre-Charge Length m |
7.5 |
Max. Elevation Difference m |
|
20 |
Piping Connection Heat Insulation |
– |
Both liquid and gas pipes |
Refrigerant Charge
|
Type – |
|
R32 |
Pre Charge g |
|
1300 |
Additional Charge g/m |
|
20 |
Control – |
|
Electronic Expansion Valve |